V_1.8.0 Jan/09/05 : (official release; upgrade from V_1.7.1)
a) New features
Allow command "interval" with 0 as minimum value
New command "display" to provide LED with normal presentation or 180 degrees rotated
Command "id" now supported in chain
b) Bug fixes
Command "interval" was not accepting values between 48 and 57
Command "list" presenting garbage if the outlet list for a user was big
Commands addressing outlet 85 were causing the chain to be lost due to memory invasion
c) Change Log
Command "ver" presents in addition the model number (e.g PM10DC = 24)
Limitation in the FW: no command can use outlet name in a range when the outlets in the range are NOT
in the same box. Outlet numbers in a range can be used in any mode.
V_1.7.1 Oct/04/05 : (official release; upgrade from V_1.7.0)
a) New features
Support again outlet name with characters between 21H to 7EH (but the first char in the name can't be numeric)
Characters ',' , '%' and '-' are reserved for internal use
b) Bug fixes
None
c) Change Log
V_1.7.0 Sep/15/05 : (official release; upgrade from V_1.6.0)
a) New features
Support to IPDU name (8 characters long)
b) Bug fixes
Status command with formatting problem in the Users field (missing a TAB)
Unassign command shows now the outlets out of the first IPDU being unassigned
Executing alarm command to set a given threshold followed by restore command would not recover the
threshold saved in flash
c) Change Log
V_1.6.0 Jul/28/05 : (official release; upgrade from V_1.5.0)
a) New features
Support to PM10i 32A, PM20i 32A, PM8iR 16A and PM10DC 10A.
Support to outlet names with 16 characters long
b) Bug fixes
Interval time was not accurate (bigger than it should be) affecting on, off and cycle commands
currentprotection command ignores parameters different from on/off
factory_defaults will turn ON all outlets w/o turning them OFF first
c) Change Log
V_1.5.0 Oct/25/04 : (official release; upgrade from V_1.4.0)
a) New features
Support to PM10i 30A.
Display blinks when over current happens
b) Bug fixes
None
c) Change Log
V_1.4.0 Oct/04/04 : (official release; upgrade from V_1.3.0)
a) New features
Support to PM20i.
Can't remove an outlet name by using command 'name' for a given outlet #(s)
List command doesn't show some of the outlets on the console
"not V_1.2.0/1 or V_1.1.0 compatible" when executing 'restore' from pmCommand with a certain type of name being set for the outlets.
typo in 'deluser' help info
a) New features
Support to PM10i.
Commands with outlets as arguments were not treating range properly.
Commands that require arguments when called without them were not returning proper error information or were getting lost
a) New features
None.
When registering one user's password greater than 8 characters the admin user would be deleted. Only powering off and back on would recover the unit.
Current reading for PM10 30A, outlets 5-10, was wrong
a) New features
None.
Upgrading from 1.1.0i to 1.2.0 could present problems in the outlet names, users and maxCurrent.
Buzzer could go off when upgrading to 1.2.0